Application: Top drive internal blowout preventer valves (DSSV-Drill Stem Safety Valves) are uesed for both blow out prevention and mud control during drilling operations. It is designed to provide a positive seal in the event of a kick.
Products Details
Application: Top drive internal blowout preventer valves (DSSV-Drill Stem Safety Valves) are uesed for both blow out prevention and mud control during drilling operations. It is designed to provide a positive seal in the event of a kick.
Design: Designed as manual and remote operated topdrive valve as well as upper and lower kelly valve.
Pressure Ratings: 5,000; 10,000 or 15,000 psi
Connections: Rotary shouldered connections such as NC, REG, IF & FH; other connection type are available on request
Features:
One-piece boy;
Improved load capacity verified by finite elements analysis;
Low friction corrosive coated stems to reduce operating torque and increase service life.
Type | OD mm(inch) | ID mm(inch) | OAL mm(inch) | Connection API | WP (Psi) | Single switch differential pressure (Psi) |
DQ40 IBOP(ON) | 187 (7 23/64) | 76(3) | 572(22 1/2) | 6 5/8REG (BOXxBOX) | 15000Psi (105MPa) | surge |
DQ40 IBOP(ON) | 547(21 17/32) | 6 5/8REG (BOXxPIN) | surge | |||
DQ40 IBOP(Under) | 523(20 19/32) | 6 5/8REG (BOXxPIN) | 8000Psi | |||
DQ70 IBOP(ON) | 197 (7 3/4) | 76(3) | 572(22 1/2) | 6 5/8REG (BOXxBOX) | 15000Psi (105MPa) | surge |
DQ70 IBOP(ON) | 547(21 17/32) | 6 5/8REG (BOXxPIN) | surge | |||
DQ70 IBOP(Under) | 523(20 19/32) | 6 5/8REG (BOXxPIN) | 8000Psi | |||
DQ90 IBOP(ON) | 216 (8 1/2) | 77.8(3 1/16) | 600(23 5/8) | 7 5/8REG (BOXxBOX) | 15000Psi (105MPa) | surge |
DQ90 IBOP(ON) | 600(23 5/8) | 7 5/8REG (BOXxPIN) | surge | |||
DQ90 IBOP(Under) | 512(20 5/32) | 7 5/8REG (BOXxPIN) | 8000Psi |
Kelly valve (IBOP) can be divided into upper kelly valve and lower kelly valve. They are a kind of control valve used with the top drive system. Normally, two kelly valves are connected in series on the top. Drive the drilling device. The valve adopts a highly reliable metal-to-metal seal and can withstand high pressure from both upper and lower sides. Its working pressure is 5000Psi to 15000Psi. If a well surge is detected, the top drive can be remotely shut down by the top drive, and the top drive can be closed manually, which is an effective way to prevent blowout.
Ordering instruction:
Any special requirement on thread type or temperature, please specify before order.
Professional sales team with rich experience in the industry; systematic document management; passed multiple product certifications and management system certifications; strong technical force